Configuring Ports 17
SCO OpenServer
Enabling Ports
To enable a port, enter this command:
enable portname
Where portname is the device name as shown in the Device Names
table. For example, to enable Board 1, Port 0 for direct
communications, enter:
enable ttyr0a
For more information, see the online manual page for enable.
Disabling Ports
To disable a port, enter this command:
disable portname
Where portname is the device name as shown in the Device Names
table. For example, to disable Board 1, Port 0, enter:
disable ttyr0a
For more information, see the online manual page for disable.
Viewing Settings
To view the current tty settings for a port, enter this command:
stty -a < /dev/portname
For more information see the Troubleshooting beginning on page 32.
Hardware Flow Control
To enable hardware flow control for a port that has already been
enabled, cd to the /comtrol/rckt directory and enter this command:
rtscts -y /dev/portname
To disable hardware flow control, enter this command:
rtscts -n /dev/portname